Hospital Units - H Series
Direct expansion

Cooling capacity: 27,1 to 118,8kW.

Air flow: from 2.500 to 11.200m3/h.


Hospital units - OHA

· Modulating electric heating battery 

· Direct expansion coil with complete refrigeration circuit

· Post-heating coil: modulating electric

· Independent modulating immersed electrode,
  immersed heating elements humidifier, or alternatively
  a modulating steam network distribution system

· Heat recovery system



DOWNLOAD THE BROCHURE

1. UNITS WITH HEAT RECOVERY

2. UNITS WITHOUT HEAT RECOVERY*

* Only for extra European markets/not compatible with ERP2018

 


Unidirectional air filtering ceiling



 

Complete electrical board


The electrical board is equipped with a door-locking main switch and necessary components for protection and normal operation of the unit.

Terminals are provided for remote connection of a cumulative alarm signal and remote control of start/stop functions.


Night stand-by


When the room in not in use the flow of fresh air can be reduced to predefined set limits, maintaining the area in overpressure, and increasing the interval for the control of temperature and humidity. The room is thus kept sterile without wasting energy.


Heat recovery


Hydronic heat recovery system.

Consisting of two water coils, one in the suction section and an identical one in the fresh air treatment section, connected by a hydraulic circuit with a pump and expansion tank. 

The hydronic heat recovery system, although its performance is lower than that of a counter-current plate or rotary system, is capable of avoiding all types of cross-contamination between exhaust and supply air.


Microprocessor Controller


New generation electronic control system with Modbus supervision.

The units feature an advanced electronic control system, conceived and designed to deliver optimum performance and easier access to information.


 



Technical equipment

 





Hospital Units - H Series


The new generation of H Series air conditioners is optimised for operating theatres and hospitals, where the primary objective is high air quality. The H Series units, in their standard configuration, are complete with all key components (heat recovery system, cooling, pre- and

post-heating, humidification and dehumidification), sized for the treatment of full fresh air or with partial recirculation.

A flexible configuration and a high number of accessories assure the use of H Series units for applications such as: operating theatres, laboratories, clean rooms, image diagnosis rooms, wards, and intensive care units.



The primary objective is high air quality