Large Data Center - G Series
Chilled Water
Cooling capacity: 55,5 to 202,8kW.
Air flow: from 11.000 to 45.200m3/h.
Close Control - UGU
· Separate air-cooling section for mounting under raised floors
· High delivered cooling capacity to footprint ratio
· Optimised air distribution in raised floor
· Reduced energy consumption of fans
· POWER Valve system for the balancing and the monitoring of the
cooling circuit
Chilled water versions available in XH (extended height).
Free cooling and two sources models available.

Efficiency and performance
High performance and lower power consumption with EC fans.
Independent management of each fan for additional redundancy.
Custom-made solutions with optimised coils to match each application requirement.

POWER Valve
The POWER Valve system allows the monitoring of the cooling circuit performance in real-time, and the automatic balancing of the water circuit without the involvement of external personnel.
Thanks to the water circuit automatic balancing, energy wastage due to water over-flow can be reduced.

SMART net
The SMART net local area network (LAN) makes it possible to actively share the workload among all the units in the group. Thanks to the distribution of workload, system efficiency can be increased by optimising the operation of the main components such as fans, compressors, electric batteries and humidifiers.
With the Multimaster system, each unit is able to take control of the local network even if communication among units is defective (broken or damaged cable), or in the case of shutdown of one of the units.
Technical equipment

Large Data Center - G Series
G Series Close Control air conditioners have construction and operating characteristics suitable for meeting the design criteria of the latest generation data centers.
Close control systems in big data centers are designed with redundancy and fault tolerance to minimise the risk of downtime due to equipment failures or maintenance activities. The units have a separate section for fans for mounting under raised floors.
Close control for large data centers is essential for maintaining optimal operating conditions to ensure the reliability, performance, and longevity of the IT infrastructure. They utilise advanced cooling technologies, chilled water or DX cooling, to efficiently remove heat, maintain stable temperatures, and optimal humidity levels throughout the data centers.
Large data center perimeter installation
Downflow air supply (UGA / UGU)


a: Version with top air intake and downflow air supply, with stand for raised floors. b: Version for raised floor below 550mm. c: Version for installation outside the data center (back delivery).